39
5
FUNCTIONS FOR RECEIVE
BLANK
CH
ANT
USB
AGCAMP
P.
SWR
ALC
Po
S
1
20 50
3
3211.5
579 20 40 60
100%
1
1
S
M1
AGCDUPCMPTCNSCP
F1
F2
F3 F4 F5
VFOA
Toggles AGC ON/OFF AGC indicators
OFF
F
5-5 1/4 function
When the 1/4 function is ON, one complete rotation of
the tuning dial changes the frequency by 1.25 kHz
(normally one rotation changes the frequency by 5
kHz). This is convenient when critical setting is re-
quired and is only available in CW and RTTY modes.
Push [CW/RTTY] to select CW or RTTY mode.
While menu set 1 is selected, push [F3](1/4) to
toggle the 1/4 function ON and OFF.
When the function is ON, 1/4 appears in the function
display.
This can be set independently for CW and RTTY modes.
When the TS function is turned ON, the TS function has
priority.
5-6 NB function
The noise blanker reduces pulse-type noise such as
that generated by automobile ignition systems. This
function is not effective for AM and FM, or non pulse-
type noise.
Push [NB] to toggle the noise blanker function ON
and OFF.
When the noise blanker function is turned ON in AM
mode and a strong signal is received, audio may distort.
In this case turn the function OFF.
BLANK
1
4
CH
VFOA
ANT
AGCAMP
P.
SWR
ALC
Po
S
1
20 50
3
3211.5
579 20 40 60
100%
1
1
F
CW
F1
F2
F3 F4 F5
M1
AGCDUP1/4KEYSCP
1/4 function ON/OFF 1/4 function indicator
[NB]
5-4 AGC function
The AGC (auto gain control) controls receiver gain to
produce a constant audio output level even when the
received signal strength is varied by fading, etc.
While menu set 1 is displayed, push [F1](AGC) one
or more times to select AGC fast or AGC slow.
The corresponding indicator appears in the display.
AGC slow cannot be selected in FM mode.
Push [F1](AGC) for 2 sec. to turn the AGC function
OFF.
AGC should normally be set to AGC fast for CW and
RTTY operation and to AGC slow for SSB and AM oper-
ation.
Turn AGC OFF when receiving a very weak signal near a
strong signal.
NOTE: When the AGC function is turned OFF, the
S-meter does not function.

Table of Contents

Other manuals for Icom IC-746

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-746 and is the answer not in the manual?

Icom IC-746 Specifications

General IconGeneral
ModeSSB, CW, RTTY, AM, FM
Receiver TypeDouble conversion superheterodyne
Antenna ConnectorSO-239
Voltage13.8 V DC ±15%
Impedance50 ohms
Output Power100 W (SSB, CW, FM, RTTY), 40 W (AM)
Current DrainTX: 20 A
SensitivityAM: 2 µV
SelectivityCW: 500 Hz (-6 dB)