Regular Inspection Plan
1. Perform regular inspection to ensure a long service life of this welder.
2. Perform regular inspection carefully, including checking and cleaning the interior of the
welder.
3. Generally, regular inspection must be performed every 6 months. However, if the site is
dusty or has heavy oily smoke, perform regular inspection every 3 months.
4. Table 4-4 provides a recommended regular inspection plan.
Table 4-4 Regular inspection plan (year: xxxx)
Regular Inspection Items
(You can add inspection items to the following items according to the actual situations.)
1. Remove dust from inside the welder.
Remove the top plate and side plates of the welder. Use dry compressed air to blow off the
spatters and dust from inside the welder. Then, remove the dirt and unexpected objects from
inside the welder.
Note
Heavy dust on the radiator affects cooling and may easily cause over-temperature protection.
2. Check the welder.
Remove the top plate and side plates of the welder. Check for signs of peculiar smells,
discoloration, or damages caused by excessive heat. Check whether the connections are
loose.
3. Check the power cables and gas tube.
In addition to daily inspection, check the grounding cables, power cables, and gas tubes more
carefully and regularly resolve fastening issues.
Voltage-Resistance Test and Insulation Test
The tests can performed only by Megmeet's after-sale service personnel or professional
personnel with knowledge on electric devices and welders.