Draco compact DVI KVM Extender
44 2021-07-09
In order to configure a redundant CPU Unit for the operation with two
competing CON Units, proceed as follows:
1. Connect a redundant CPU Unit to any source (computer, CPU) by
using a mini USB connection.
2. Open the file "Config.txt" that is located on the appearing flash drive
of the extender.
3. Activate the release timer by writing the parameter RELEASETIME=n
into the second line. The variable "n" defines the time in seconds and
has to be replaced by the numbers 0 to 9 (e.g. RELEASETIME=5).
If this parameter is not activated at all, the release time is set to
2 seconds by default.
The parameter RELEASETIME=X deactivates the shared operation.
4. Save your changes.
5. Reboot the CPU Unit.
Example View – Config.txt
When using redundant CP
U Units in combination with a KVM matrix, the
function of competing control will be automatically deactivated in the
extender and will have to be performed by the
KVM matrix.