EasyManua.ls Logo

Inovance MD500 Series - Acceleration;Deceleration Time and S-Curve Setting

Inovance MD500 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. Description of Parameters
- 122 -
6
6.3.3 Acceleration/Deceleration Time and S-curve Setting
Acceleration time indicates time required by the AC drive to accelerate from 0 Hz to acceleration/
deceleration time base frequency (F0-25).
Deceleration time indicates time required by the AC drive to decelerate from acceleration/
deceleration time base frequency (F0-25) to 0 Hz.
Figure 6-35 Acceleration/Deceleration time
Time (t)
Output frequency (Hz)
Frequency reference
Accel./decel. time
base frequency
t1
t2
Set accel. time
Set decel. time
Actual accel. time
Actual decel. time
The AC drive provides totally four groups of acceleration/deceleration time for selection. You can
perform switchover by using a DI terminal.
Group 1: F0-17, F0-18
Group 2: F8-03, F8-04
Group 3: F8-05, F8-06
Group 4: F8-07, F8-08
For example, select DI7 and DI8 for switchover.
Related function parameters are set as follows:
Function Code Parameter Name Setting Function Description
F4-06
DI7 function selection 16 Terminal 1 for acceleration/deceleration
time selection
F4-07
DI8 function selection 17 Terminal 2 for acceleration/deceleration
time selection
Two terminals for acceleration/deceleration time selection have four state combinations, as listed
in the following table.
Terminal 2 Terminal 1 Accel/Decel Time Selection Corresponding Pr.
OFF OFF Accel/Decel time 1 F0-17, F0-18
OFF ON Accel/Decel time 2 F8-03, F8-04
ON OFF Accel/Decel time 3 F8-05, F8-06
ON ON Accel/Decel time 4 F8-07, F8-08

Table of Contents

Related product manuals