6. Description of Parameters
- 159 -
6
Function Code Parameter Name Setting Range Default
A2-08
Leakage inductive
reactance
0.01 to 655.35 (AC drive power ≤ 55 kW)
0.001 to 65.535 (AC drive power > 55 kW)
Auto-tuning
parameter
A2-09
Mutual inductive
reactance
0.1 to 6553.5 (AC drive power ≤ 55 kW)
0.01 to 655.35 (AC drive power > 55 kW)
Auto-tuning
parameter
A2-10
No-load current 0.01 to F1-03 (AC drive power ≤ 55 kW)
0.1 to F1-03 (AC drive power > 55 kW)
Auto-tuning
parameter
A2-27
Encoder pulses per
revolution
1 to 65535 1024
A2-28
Encoder type 0 to 2 0
A2-29
Speed feedback PG
selection
0 to 2 0
A2-30
A/B phase sequence
of ABZ incremental
encoder
0 to 1 0
A2-31
Encoder installation
angle
0.0 to 359.9 0.0
A2-34
Number of pole pairs
of resolver
1 to 65535 1
A2-37
Auto-tuning selection 0 to 3 0
6.8.5 User Programmable Card
You can implement control of the AC drive by PLC programming by connecting user
programmable card MD38PC1 to the drive to satisfy various process requirements.
For details of MD38PC1, see the User Programmable Card User Manual. The function of this
card must be used together with parameters in group A7.
Figure 6-52 User programmable function
A7-00 = 1
Set the programmable
card to activate.
Jumper
J2
Jumper
J3
DIP switch S1
(The grey indicates ON.)
Setting of
A7-02
1
2 3
4 5 6 7 8
0
1 2
3 4
5 6 7 8
1
1 2
3
4
5 6
7 8
2
1
2
3 4
5 6 7
8
3
Any
1 2
3 4
5 6
7 8
4
Any
1 2 3
4
5
6 7
8
5
Any
1
2 3 4
5 6
7 8
6
Any
1
2 3 4
5 6
7 8
7
Voltage input
Voltage output
AI3 AO2
Current output
Voltage output
Current output
Voltage output
Current output
Voltage output
Current output
Voltage input
Current input
Current input
PTC input
PTC input
PT100 input
PT100 input
Set the
function of AI
and AO on
the card.

Table of Contents