6. Description of Parameters
- 82 -
6
Chapter 6 Description of Parameters
6.1 Start/Stop Command Source
Three control methods are available:
Operating panel (keypad & display)
Terminal I/O control
Serial communication
You can select the required control mode in function parameter F0-02.
Function Code Parameter Name Setting Range Default
F0-02
Command source selection 0: Operating panel (keypad & display) (LED off)
1: Terminal I/O control (LED on)
2: Serial comms. (LED ashing)
0
F0-02 = 0: Operating panel (keypad & display) (The LOCAL/REMOT indicator is off.)
The RUN commands are given by pressing keys
RUN
and
STOP
RES
on the operating panel.
Press
RUN
to start the AC Drive.
Press
STOP
RES
to stop the AC Drive.
For details on operating panel, refer to
C
h
a
p
t
e
r
4
O
p
e
r
a
t
i
n
g
P
a
n
e
l
(
K
e
y
p
a
d
&
D
i
s
p
l
a
y
)
.
F0-02 = 1: Terminal I/O control (The LOCAL/REMOT indicator is on.)
The terminal I/O control mode applies to installations where the Start and Stop signals come from:
A DIP switch or electromagnetic button, or
A dry contact signal source
Commands are given by using multi-functional input terminals with functions such as FWD, REV,
JOGF and JOGR.
For details on terminal I/O control, see
6
.
1
.
1
T
e
r
m
i
n
a
l
I
/
O
C
o
n
t
r
o
l
.
F0-02 = 2: Serial comms (The LOCAL/REMOT indicator is ashing.)
The available serial communication options are Modbus, PROFIBUS-DP, CANlink, CANopen.
For details on serial communication, see
6
.
1
.
2
S
e
r
i
a
l
C
o
m
m
u
n
i
c
a
t
i
o
n
.