AC drive fault description
AC Drive
Fault Address
AC Drive Fault Information
8000 0000: No fault
0001: Reserved
0002 Overcurrent during
acceleration
0003: Overcurrent during
deceleration
0004: Overcurrent at constant
speed
0005: Overvoltage during
acceleration
0006: Overvoltage during
deceleration
0007: Overvoltage at constant
speed
0008: Buffer resistor overload
0009: Undervoltage
000A: AC drive overload
000B: Motor overload
000C: Power input phase loss
000D: Power output phase loss
000E: Module overheat
000F: External fault
0010: Communication fault
0011: Contactor fault
0012: Current detection fault
0013: Motor auto-tuning fault
0014: Encoder/PG card fault
0015: Parameter read and write fault
0016: AC drive hardware fault
0017: Motor short circuited to ground
0018: Reserved
0019: Reserved
001A: Accumulative running time reached
001B: User-dened fault 1
001C: User-dened fault 2
001D: Accumulative power-on time
reached
001E: Load lost
001F: PID feedback lost during running
0028: Fast current limit timeout
0029: Motor switchover error during
running
002A: Too large speed deviation
002B: Motor over-speed
002D: Motor overheat
005A: Incorrect setting of PPR of the
encoder
005B: Not connecting the encoder
005C: Initial position error
005E: Speed feedback error
7.5.5 Group Fd Communication Parameter Description
Function Code Parameter Name Setting Range Default
Fd-00 Baud rate Units position (Modubs)
0: 300 bps
1: 600 bps
2: 1200 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps
8: 57600 bps
9: 115200 bps
5005