Appendix. Parameter Table   
- 309 -
A.2  Standard Parameters
Parameter 
No.
Parameter Name Setting Range Default Property Page
Group F0: Standard Parameters
F0-00 G/P type display 1 and 2 Model 
dependent
●
-
F0-01 Motor 1 control mode 0 to 2 0
★
-
F0-02 Command source selection 0 to 2 0
☆
8
2
 
F0-03 Main frequency reference 
setting channel selection
0 to 9 0
★
9
0
 
F0-04 Auxiliary frequency reference 
setting channel selection
0 to 9 0
★
1
1
1
 
F0-05 Base value of range of auxiliary 
frequency reference for Main 
and auxiliary calculation
0, 1 0
☆
1
1
4
 
F0-06 Range of auxiliary frequency 
reference for main and auxiliary 
calculation
0% to 150% 100%
☆
1
1
4
 
F0-07 Final Frequency reference  
setting selection
00 to 34 00
☆
1
1
4
 
F0-08 Preset frequency 0.00 to max. frequency (F0-10)   50.00 Hz
☆
9
2
 
F0-09 Running direction 0, 1 0
☆
1
9
4
 
F0-10 Max. frequency 50.00 to 500.00 Hz 50.00 Hz
★
1
1
6
 
F0-11 Setting channel of frequency 
upper limit
0 to 5 0
★
1
1
6
 
F0-12 Frequency reference upper 
limit
Frequency lower limit (F0-14) 
to max. frequency (F0-10)
50.00 Hz
☆
1
1
6
 
F0-13 Frequency reference upper 
limit offset
0.00 Hz to max. frequency (F0-
10)
0.00 Hz
☆
-
F0-14 Frequency reference lower limit 0.00 Hz to frequency upper 
limit (F0-12)
0.00 Hz
☆
1
1
6
F0-15 Carrier frequency Model dependent Model 
dependent
☆
-
F0-16 Carrier frequency adjusted with 
temperature
0: Disabled
1: Enabled
1
☆
-
F0-17 Acceleration time 1 0.00s to 650.00s (F0-19 = 2)
0.0s to 6500.0s (F0-19 = 1)
0s to 65000s (F0-19 = 0)
Model 
dependent
☆
1
2
3
 
F0-18 Deceleration time 1 0.00s to 650.00s (F0-19 = 2)
0.0s to 6500.0s (F0-19 = 1)
0s to 65000s (F0-19 = 0)
Model 
dependent
☆
1
2
3
F0-19 Acceleration/Deceleration time 
unit
0: 1s
1: 0.1s
2: 0.01s
1
★
1
2
3
 
F0-21 Frequency offset of Auxiliary 
frequency setting channel for 
main and auxiliary calculation
0.00 Hz to max. frequency (F0-
10)
0.00 Hz
☆
-