10. Maintenance and Inspection
- 287 -
10.2.2 Insulation Test on Main Circuit
● Before measuring insulation resistance with megameter (500 VDC megameter
recommended), disconnect the main circuit from the AC drive.
● Do not conduct the dielectric strength test. High voltage (> 500 V) test need not
be performed again because it has been completed before delivery.
Figure 11-1 Test insulation on the main circuit
R S
T
U
V
W
BR
P
+
-
500 VDC
Megameter
+
-
MD500
The measured insulation resistance must be greater than 5 MΩ.
Before test, remove the VDR screw, as shown in the following position.
VDR jumper screw
EMC jumper scew
1