10. Maintenance and Inspection
- 287 -
10
10.2.2 Insulation Test on Main Circuit
Note
Before measuring insulation resistance with megameter (500 VDC megameter
recommended), disconnect the main circuit from the AC drive.
Do not conduct the dielectric strength test. High voltage (> 500 V) test need not
be performed again because it has been completed before delivery.
Figure 11-1 Test insulation on the main circuit
R S
T
U
V
W
BR
P
+
-
500 VDC
Megameter
+
-
MD500
The measured insulation resistance must be greater than 5 MΩ.
Before test, remove the VDR screw, as shown in the following position.