116
10. Reboot the system.
11. When prompted, press
CTRL+M to enter the MegaRAID utilities.
12. Enable the RAID BIOS and then exit the utilities.
Setting the Default RAID Configuration
InterServe 650, 660
To set the default RAID configuration for the InterServe 650, 660:
1. Reboot the system.
2. When prompted, press
CTRL+M to enter the MegaRAID utilities.
3. Use Configuration/Easy Configuration to set up one 8 GB array to RAID level 5, write through,
and cache I/O.
4. Under Objects/Adapter/Chipset Type, ensure that “Others” is selected.
5. Under Objects/Adapter/Alarm Control Type, ensure that the MegaRAID onboard alarm is
disabled.
6. Under Objects/Adapter/Spin Up Time/Spinup Parameters, set the parameter to two drives every
six seconds.
7. Under Objects/Adapter/Ultra SCSI, ensure the Ultra SCSI is disabled.
8. Reboot the system.
StudioZ RAX
Refer to Chapter 2 “Configuring the System,” in the StudioZ RAX System Setup for information about
default RAID configuration for the StudioZ RAX.