62 Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
1.2.9.2.m.n.2 Run/Stop test
2 Run test?
>Yes<
Run battery test.
Test duration is set in “1.2.9.2.m.n.1 Test timeon page 61.
If battery test for this device is already running, you are prompted to stop this
test.
1.2.10 Panel diag
1>System V/A
2 Battery V
Panel diagnostic allows you to monitor particular electrical data, for example,
current and voltage.
1.2.10.1 System V/A
System voltage:
13.8V
System current:
0.8A
The scrolled screens show the system power supply voltage and current.
1.2.10.2 Battery (V)
Battery voltage:
12.8V
The screen shows the battery voltage.
1.2.11 Check card
Badge card
Keypad 1
Use the menu to read data from a user card.
Badge card on the keypad indicated on the screen the same way as it is done
when user card programming (see “Adding a cardon page 86).
Note: The keypad for user card programming is defined in 8.8.6 Card learn-in
on page 159.
If the card is programmed in the system, its holder user information is displayed:
User 05
J.Smith
Otherwise, if the card is unknown, its type and data is displayed in the same
format as in the event log.
CARD/TAG
98832665774

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Advisor Advanced ATS2000A-MM and is the answer not in the manual?

Interlogix Advisor Advanced ATS2000A-MM Specifications

General IconGeneral
BrandInterlogix
ModelAdvisor Advanced ATS2000A-MM
CategoryControl Panel
LanguageEnglish

Related product manuals