Chapter 5 Troubleshooting
Chapter 5 Troubleshooting
5.1 Operation as IP (Scale and Printer)
This section describes the procedure to use the wrapper as an IP (scale or printer only) in case that the
wrapper is disabled due to a trouble, etc.
1 Turn OFF the power of the wrapper unit.
2 Turn ON the power of the wrapper unit as shown in Fig. 1.
3 With the condition above, press the emergency stop button of the wrapper unit.
4 With the condition above, press the return key of the wrapper unit for 11 times. The screen in fig. 1
will be released and returned to the normal screen.
5 The wrapper unit can be used as an IP (weigh price labeler).
Press this button for 11
Fig. Screen when the power is ON.
5-1