Chapter 5 Troubleshooting
ID NO.
TITLE ERROR CONTENTS SOLUTION
0725 No second label
printing
Cannot print the second label.
The 2
nd label format No. is not
being [36 (Nutrition Format)]
when it set [YES] at Nutrition
printing with preset key [NIP
Y/N].
Program the 2
nd label format No.
to [36].
- This is for Nutrition of New
Zealand
[OK]
5.3.7 Error related to scale (Code 1600s)
ID NO.
TITLE ERROR CONTENTS SOLUTION
1600 VALUE FOR
SCALE MEMORY
IS WRONG
Memory setting of the scale is
abnormal.
Setting contents between scale
side and console side do not
match.
[OK]
It is necessary to implement
calibration.
1601 SPAN
ADJUTMENT FOR
SCALE IS NOT
COMPLETED
Span adjustment for scale is not
completed.
[OK]
It is necessary to implement
calibration.
1602 SCALE
INITIALIZATION IS
NOT COMPLETED
Initialization for scale is not
completed.
[OK]
It is necessary to implement
calibration.
1620 SCALE IS
BLACKOUT
Scale is blackout temporary.
[OK]
Reboot the machine.
1621 NO RESPONSE
FROM SCALE
There is no response from the
scale.
[OK]
Reboot the machine after confirming
the connection of the scale.
1622 CANNOT
COMMUNICATE
WITH SCALE
Cannot communicate with the
scale.
[OK]
Reboot the machine after confirming
the connection of the scale.
1623 CANNOT
COMMUNICATE
WITH SCALE
Cannot communicate with the
scale.
[OK]
Reboot the machine after confirming
the connection of the scale.
1624 DATA SET ERROR Error for setting tare weight.
Entered vale was not following
the scale division or over the
maximum tare value.
<Sub-error>
0000:USA 0001:Others
[OK]
When entering the tare value, it must
be lower than the maximum tare value
and following the scale division.
5-28

Table of Contents

Other manuals for ISHIDA WM-NANO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA WM-NANO and is the answer not in the manual?

ISHIDA WM-NANO Specifications

General IconGeneral
BrandISHIDA
ModelWM-NANO
CategoryPackaging equipment
LanguageEnglish