Chapter 5 Troubleshooting
5.3 Error List
5.3.1 Error relates to System (Code 100s)
ID NO.
TITLE ERROR CONTENTS SOLUTION
0101 SYSTEM ERROR System became unstable.
It could not implement the dynamic
allocation (malloc) in the memory.
(The memory for program to work
became full.)
leaking of the memory
REBOOT
0102 SEQUENCE
ERROR
There was an out of alignment on
the product sequence.
The machine is managing the
wrapping/printing movement by
putting the sequence numbers on
each product. But, at this time, the
declination of management of
sequence number occurred between
the main software and peripheral
devices, and the machine could not
continue wrapping movement.
[RETURN]
0103
PRINTER 1 ERROR
The machine tried to connect to the
printer No. that does not exist.
<SUB ERROR No.>
0000:Printer 1 0001:Printer 2
0002:Printer 3 0003:Printer 4
[RETURN]
0105 INITIALIZATION
FAILED
The machine failed to initialize the
memory.
After the board is replaced, the
memory initialization has not been
implemented.
[OK]
Implement the memory initialization.
0106
BATTERY IS FAULT
Either the battery is consumed or
switch for the battery is OFF.
[OK]
When the battery switch is OFF, turn
ON the battery switch.
When the battery switch is ON, as the
battery is consumed, the replacement
of the board is necessary. (The battery
is embedded to the board.)
0107
TOUCH SCREEN
ADJUSTMENT IS
NOT COMPLETED
YET
The adjustment of the touch panel is
not completed.
After the board is replaced, the
adjustment of touch panel is not
implemented yet.
[OK]
Implement the adjustment of the touch
panel.
5-3