Chapter 3 Adjustment Mode
6 Remove the film conveying unit directly upward.
NOTE:
In removing the film conveying unit, pay attention
not to hit the film detection sensors (at 2 locations).
NOTE:
In removing the film conveying unit, lift the unit
directly upward so that it does not get stuck with the
solenoid and clamp fittings (left side: 2 locations,
right side: 2 locations).
7 Place the film conveying unit upside down.
Right
lateral
Solenoid and clamp fittings
(Left side: 2 locations, Right side:
2 locations)
Film detection sensors (2 locations)
Upside
3-20