Chapter 3 Adjustment Mode
■ Mounting the Film Conveying Unit
1) Place the film conveying unit directly from the above.
NOTE:
In mounting the film conveying unit, pay attention
not to hit the film detection sensors (at 2 locations).
NOTE:
In mounting the film conveying unit, insert the
solenoid and clamp fittings (left side: 2 locations,
right side: 2 locations) into the solenoid holes.
2) Pull out the film conveying unit into a full forward
condition. (Close up the idle gap created in the
front.)
3) Tighten the screws (4) at the four corners to fix
the film conveying unit.
Right
lateral
Solenoid and clamp fittings
(Left side: 2 locations, Right side:
2 locations)
Film detection sensors (2 locations)
Insert into the hole.
3-26