HS-1RL User’s Manual Page 22
Trigger Time Out
This sets the maximum time how trigger procession continues during a scan attempt.
This command is not valid in Presentation Trigger Mode.
Use the command TRGTIME x (where ‘x’ is a value between 0 and 300,000 in 1ms steps), to set
the time between 1ms and 300 seconds.
Default = 9900 (9.9 Seconds).
Note: TRGTIME 0 = infinite trigger time out.
Setting examples:
Trigger Time Out 1.0 seconds Trigger Time Out 5.0 seconds
* Trigger Time Out 9.9 seconds Trigger Time Out 30.0 seconds
Good Read Delay
This sets the time period before the scanner can read another bar code.
Use the command DLYGDRD x (where x’ is a value between 0 and 30.000 milliseconds), to set
the time between 0 (no delay) and 30.000 (=30 sec).
Default time = 0 Seconds.
Note: Good Read Delay is most effective when in Presentation Mode or when Multiple Symbol
Mode is turned on in combination with the other Trigger Modes.
Setting examples:
* No Good Read delay Good Read delay 0.2 seconds
Good Read delay 0.5 seconds Good Read delay 1.0 seconds