HS-1RL User’s Manual Page 26
Barcode Prefix
Prefix characters are user-definable data characters that can be sent before scanned data.
It’s possible for the HS-1RL to enable and set a specific prefix for all scanned barcode data only.
This can help to discern barcode data from RFID data when both are output alternately.
Note: This Barcode Prefix will be separate from any set RFID prefixes.
Barcode Prefixes On/Off
To enable or disable barcode prefixes, scan the appropriate code below.
Default = disabled.
Enable * Disable
Barcode Prefix Block String
Use the command PREBBLK in combination with ASCII or hex characters to set the
specific Barcode Prefix string. See Appendix D for ASCII/hex conversion help.
Note: Hex characters must be preceded by \x and it’s not possible to interject a Carriage
Return in the middle of the block string.
For instance, if you want the prefix to be [BC-data], send: PREBBLK [BC-data].
Please contact JADAK if you need further help.
The default Barcode Prefix Block string is: (B)
* Barcode Prefix Block (B)
Example codes:
Barcode Prefix Block B/ Barcode Prefix Block [BC]