3 Operating Conditions
30 Jetter AG
Operating Parameters
Environment
Parameter(s) Value(s) Reference
standard
Operating conditions Temperature: 0 °C to +45 °C
(+45 °C to +55 °C:
Derating 2.5 %/K)
Air humidity:
5 % to 85 %, non-condensing
DIN EN 50178
Storage conditions
(units within packing)
Temperature: -25 °C bis +55 °C,
maximum fluctuation: 20 K/h
Air humidity:
5 % to 95 %, non-condensing
Maximum storage period:
1 year without restrictions.
If this storage time has been
exceeded, the device must be
connected for at least 2 hours to
the mains voltage prior to
commissioning. The motor must
remain de-energized and the
logics circuit must be supplied with
power.
The servo amplifier can then be
used again without restriction.
DIN EN 50178
Transport conditions
(units within packing)
Temperature: -25 °C to +70 °C
Air humidity:
5 % to 95 %, non-condensing
DIN EN 50178
Pollution degree 2 DIN EN 50178
Corrosion immunity /
chemical resistance
No special protection against
corrosion. Ambient air must be
free from higher concentrations of
acids, alkaline solutions, corrosive
agents, salts, metal vapors, or
other corrosive or electro-
conductive contaminants
-
Operating altitude 1,000 m max. above sea level
without derating.
From 1,000 to 2,000 m above sea
level; derating 1.5 % per 100 m
increase in alitude
DIN EN 50178