EasyManua.ls Logo

Jetter JetMove D203 - Page 32

Jetter JetMove D203
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Operating Conditions
32 Jetter AG
The following note must be observed for the amplifier models JM-D203-JC24X-EIP...
NOTICE
The quality of the Ethernet cable has a significant influence on the EMC values
given in the following tables.
Use a CAT6 cable (S/FTP design) as Ethernet cable.
Operating Parameters
EMI - Emitted Interference
Parameter(s) Value(s) Reference
standard
Enclosure Frequency band
30 ... 230 MHz, limit 40 dB
(
µ
V/m) in 10 m
Frequency band
230 ... 1000 MHz, limit 47 dB
(µV/m) in 10 m
(Electromagnetic environment in
public power systems, installation
in category 2)
DIN EN 61800-3
Alternating network
current
Frequency bands:
0.15 ... 0.5 MHz, limit 79 dB
(
µ
V)*
0.5 ... 30 MHz, limit 73 dB (µV)*
* Measuring by means of the
quasi-peak detector
(Electromagnetic environment in
public power systems, installation
in category 2)
DIN EN 61800-3
NOTICE
This is a product of restricted availability according to IEC/EN 61800-3 and may
cause radio interferences in a residential environment.
Follow the instructions below:
If this product is used in a residential environment, take appropriate
measures. One of the measures is to use additional line filters. See
"Line filter" on page 39.