SECTION 6 - JLG CONTROL SYSTEM
3121813 – JLG Lift – 6-7
6.5 ADJUSTING PARAMETERS USING THE
HAND HELD ANALYZER
Once you have gained access to level 1, and a personality
item is selected, press the UP or DOWN arrow keys to
adjust its value, for example:
PERSONALITIES:
DRIVE ACCEL 1.0s
There will be a minimum and maximum for the value to
ensure efficient operation. The Value will not increase if
the UP arrow is pressed when at the maximum value nor
will the value decrease if the DOWN arrow is pressed and
the value is at the minimum value for any particular per-
sonality. If the value does not change when pressing the
up and won arrows, check the access level to ensure you
are at access level 1.
6.6 MACHINE SETUP
When a machine digit item is selected, press the UP or
DOWN arrow keys to adjust its value, for example:
GROUND ALARM:
2 = DRIVE
The effect of the machine digit value is displayed along
with its value. The above display would be selected if the
machine was equipped with a ground alarm and you
wanted it to sound when driving. There are certain set-
tings allowed to install optional features or select the
machine model.
When selection the machine model to match the size of
the machine, the personality settings will all default to the
factory recommended setting.
NOTE: Refer to Table 6-2, Personality Ranges/Defaults, and
Table 6-1, Machine Setup Descriptions in this Ser-
vice Manual for the recommended factory settings.
NOTE: Password 33271 will give you access to level 1,
which will permit you to change all machine person-
ality settings.
PERSONALITIES:
DRIVE ACCEL 1.0s
GROUND ALARM:
2=DRIVE

Table of Contents