80
K CODE
C10 F02 C10 F07 C10 F08
DESCRIPTION
Unsuccessful self-test on power up
EXPLANATION
A software command was invalid or the hardware is set up wrong for the model
ACTION
Restart the balancer . If these codes persist, Reset brand and model with C47
C CODE
C47
K CODE
C10 800
DESCRIPTION
AC power supply is below 170V, (25% below 230V)
EXPLANATION
The balancer is powered by 230VAC. In order to operate correctly and precisely, the
balancer must be supplied the proper mains voltage. The microprocessor constantly
monitors the mains power supply line. If the power line drops below 170V, C10 800 is
displayed to alert the operator to check mains power line voltage.
ACTION
Check the power line voltage. The balancer must be on a dedicated 230 Volt Main.
Avoid use of long extension cords or share the power source with large electric machi-
nery. If the mains power line is OK, check the mains power connections inside the unit.
C CODE
C55
CODE
C10 801 C10 804
DESCRIPTION
AC power supply is above 265V, (15% above 230V)
EXPLANATION
In order to operate correctly and precisely, the balancer must be supplied the proper
mains voltage. The microprocessor constantly monitors the mains power supply line.
Because voltages above 265VAC can damage the product, the C10 801 diagnostic
code is displayed to warn operator to check power line voltage.
ACTION
Check the power line voltage. The balancer must be on a dedicated 230 Volt Main. If
the mains power line is OK, check the mains power connections inside the unit
C CODE
C55,
K CODE
C10 810
DESCRIPTION
VCC below 4,8V
EXPLANATION
The 5 VDC source is used to power electronics circuits. If it is too low, the electronics
will fail to properly operate
ACTION
Check the DC voltage. Check the connectors, plugs and wires. If necessary replace
the Integrated Dispaly
C CODE
C55, C110
K CODE
C10 811
DESCRIPTION
VCC above 5.2V
EXPLANATION
The 5 VDC source is used to power electronics circuits. If it is too high, the electronics
will fail to properly operate or could be damaged
ACTION
Check the DC voltage. Check the connectors, plugs and wires. If necessary replace
the Integrated Dispaly
C CODE
C55, C110