67
0X001023 SPEED FLUCTUATION DURING THE MEASUREMENT
Check the belt tension.
If the problem still persists:
Check the speed with C60.
If the problem still persists:
Check Optoencoder with C54.
If the problem still persists:
Check the capacitor
If the problem still persists:
Call Snap On
C Codes
C28, C54, C60
0X001024 NOISY SIGNAL FROM TRANSDUCERS DURING MEASURING RUN
Check if the machine is well placed on the ! oor.
If the problem still persists:
Check if the balancer components vibrate.
If the problem still persists:
Check the belt tension.
If the problem still persists:
Check the bearings.
If the problem still persists:
Check the transducers
If the problem still persists:
Check if the vibratory assu is well secured to the cabinet.
If the problem still persists:
Call Snap On
C Codes
C28
0X001030 POWER FAIL
Check the Power supply to wall plug
If the problem still persists:
Check the main power supply cord and plug.
If the problem still persists:
Check the main switch.
If the problem still persists:
Check the main power supply with C55.
If the problem still persists:
Check VCC with C110.
If the problem still persists:
Check power supply cable and connectors inside of the machine.
If the problem still persists:
Call Snap On
C Codes C55, C110
0X001031 TEMPERATURE SENSOR
Check the main shaft Optoencoder ! at cable.
If the problem still persists:
Check the main shaft Optoencoder.
If the problem still persists:
Check the IBP box
If the problem still persists:
Call Snap On
C codes C57, C85, C86, C115, C84, C88