EasyManuals Logo

Jungheinrich TFG 430 User Manual

Jungheinrich TFG 430
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
47
08.11 EN
1.2 LPG system relief valve
LPG powered trucks are fitted with a relief
valve. This is located on the rear cover next
to the gas bottle.
In the event of a fault the pressure in the
gas system is restricted to a maximum
level. The relief valve is fitted with a
plastic cover (45).
When the valve is activated the plastic
cover comes off, thereby clearly
indicating a fault in the gas system.
In this event the truck must not be operated.
The gas system must be check by suitably qualified and trained personnel.
The user must check that the plastic cover is present each time he uses the truck.
DANGER!
Danger from escaping liquid gas.
Liquid gas can escape from faulty gas hoses.
XUse only gas bottles with an integrated line break safety valve.
XThe gas bottle connection is also fitted with a line break safety valve which prevents
the gas from escaping accidentally during operation.
XWhen replacing, always use a gas bottle connection with an integrated line break
safety valve.
49

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich TFG 430 and is the answer not in the manual?

Jungheinrich TFG 430 Specifications

General IconGeneral
BrandJungheinrich
ModelTFG 430
CategoryForklifts
LanguageEnglish

Related product manuals