53
08.11 EN
3.2 Liquid gas tank
Refillable liquid gas tanks contain a dispensing valve (66), a filling stop valve (64), a
relief valve (65) and a display (62).
Filling refillable liquid gas tanks (optional
equipment).
Requirements
– Note all guidelines and regulations
concerning the filling of LPG bottles on the
LPG pump.
Procedure
• Close the dispensing valve (66).
• Unscrew the cap (63) of the filling stop valve
(64).
• Screw the filling connection of the liquid gas
pump onto the filling stop valve (64).
Z Fuelling automatically ends when the tank's
capacity has been reached.
• After fuelling, unscrew the filling connection and screw the cap (63) of the filling
stop valve (64) back on.
66
64
63
65
62