Related
Documentation
Rack Requirements for an MX150 on page 23•
• Cabinet Requirements for an MX150 on page 24
• Clearance Requirements for Airflow and Hardware Maintenance for an MX150 on
page 25
Mounting an MX150
Table 27 on page 78 lists the methods you can use to mount an MX150.
Table 27: MX150 Mounting Methods
CommentsDevice ModelMounting Method
On a desk or other level surface by using rubber feet provided with
the device.
•
MX150Desk or other level surface
On two posts in a 19-in. rack or cabinet by using the mounting
brackets.
•
MX150Two-post rack or cabinet
•
On four posts in a 19-in. rack or cabinet by using the separately
orderable four-post rack-mount kit
•
On two posts in a 19-in. rack or cabinet by using the two-post
rack mounting brackets.
•
MX150Four-post rack or cabinet
On a wall by using separately orderable wall-mount kitMX150Wall Mounting
The holes in the mounting brackets are placed at 1 U (1.75 in. or 4.45 cm) apart so that
the switch can be mounted in any rack or cabinet that provides holes spaced at that
distance.
See the Related Documentation for detailed descriptions of the various rack or cabinet
mounting options.
Related
Documentation
Mounting an MX150 on a Desk or Other Level Surface on page 78•
• Mounting an MX150 on Two Posts in a Rack on page 79
• Mounting an MX150 on Four Posts in a Rack or Cabinet on page 81
• Connecting Earth Ground to an MX150 on page 85
Mounting an MX150 on a Desk or Other Level Surface
You can mount an MX150 on a desk or other level surface by using the four rubber feet
that are shipped with the router. The rubber feet stabilize the chassis.
Before mounting the MX150 on a desk or other level surface:
Copyright © 2017, Juniper Networks, Inc.78
MX150 3D Universal Edge Router Hardware Guide