CHAPTER 11
Connecting the MX150
•
Connecting Earth Ground to an MX150 on page 85
•
Connecting AC Power to an MX150 on page 86
Connecting Earth Ground to an MX150
Earth grounding is recommended, but optional for the MX150. The device functions
normally without earth grounding.Electromagnetic compatibility (EMC) and electrostatic
discharge (ESD) requirements are met by the chassis. The AC power cord provides surge
protection.
To connect MX150 to earth ground, you must use the protective earthing terminal on the
device chassis. See Figure 16 on page 86.
This topic describes:
•
Parts and Tools Required for Connecting an MX150 to Earth Ground on page 85
•
Connecting Earth Ground to an MX150 on page 86
Parts and Tools Required for Connecting an MX150 to Earth Ground
Table 28 on page 85 lists the earthing terminal location, grounding cable requirements,
grounding lug specifications, screws and washers required, and the screwdriver needed
for connecting a device to earth ground. Before you begin connecting a switch to earth
ground, ensure you have the parts and tools required for your device.
Table 28: Parts and Tools Required for Connecting an MX150 to Earth Ground
Additional
InformationScrewdriver
Screws and
Washers
Grounding Lug
Specifications
Grounding Cable
Requirements
Earthing
Terminal
LocationDevice
Phillips (+)
number 2
•
Two 10-32
x .25 in. screws
with #10
split-lock
washer—
not provided
•
Two #10 flat
washers—not
provided
Panduit
LCC10-14BWL or
equivalent—
not provided
14 AWG (2 mm²),
minimum 90°C wire,
or as permitted by
the local code
Rear panel
of chassis
MX150