CAUTION: Forced shutdown can result in data loss and corruption of the file
system.
NOTE: To remove power completely from the device, unplug the AC power
cord or switch off the power source.
After powering off a power supply, wait at least 10 seconds before turning it
back on. After powering on a power supply, wait at least 10 seconds before
turning it off.
The Power button on the services gateway is a standby power switch.
If you press the Power buttonto power off the device when it is still connected
to a power source, 12-V power will still be available in the chassis and the
device will be fully powered off.
NOTE: When you are powering off the device, the system displays the
following message: Turning the system power off. You can now safely remove
the power cable to completely disconnect the power from the device.
NOTE: You can use the request system reboot command to schedulea reboot
of the services gateway.
For more information about halting, powering off, or rebooting the services gateway using
the CLI, see the following topics:
Initial Configuration for Security Devices
Monitoring and Troubleshooting for Security Devices
Related
Documentation
Powering On the SRX110 Services Gateway on page 80
Resetting the SRX110 Services Gateway on page 114
Connecting the SRX110 Services Gateway to the Power Supply on page 79
Grounding the SRX110 Services Gateway on page 72
Using the Reset Config Button on the SRX110 Services Gateway on page 115
SRX110 Services Gateway Front Panel and Back Panel Views with 3G and Integrated
VDSL2
SRX110 Services Gateway LEDs
Copyright © 2015, Juniper Networks, Inc.82
SRX110 Services Gateway Hardware Guide for H2 Model Numbers

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX110 H2 and is the answer not in the manual?

Juniper SRX110 H2 Specifications

General IconGeneral
Form FactorDesktop
VPN Throughput65 Mbps
Maximum Concurrent Sessions16, 000
Memory1 GB DRAM
Flash Memory256 MB
Power SupplyExternal AC adapter
Humidity10% to 90% non-condensing
Weight2.5 lbs
Operating Temperature32°F to 104°F (0°C to 40°C)
Ports8 x 10/100/1000BASE-T