CHAPTER 5
Power Requirements and Specifications
SRX110 Services Gateway Site Electrical Wiring Guidelines on page 37
SRX110 Services Gateway Electrical and Power Requirements on page 38
SRX110 Services Gateway Power Specifications and Requirements on page 39
SRX110 Services Gateway Site Electrical Wiring Guidelines
Table 20 on page 37 describes the factors you must consider while planning the electrical
wiring for the services gateway at your site.
CAUTION: It is particularly important to provide a properly grounded and
shielded environment and to use electrical surge-suppression devices.
CAUTION: For devices with AC power supplies, an external surge protective
device (SPD) must be used at the AC power source.
Table 20: Site Electrical Wiring Guidelines for the Services Gateway
GuidelineSite Wiring Factor
To ensure that signaling functions optimally:
Install wires correctly.
Improperly installed wires can emit radio interference.
Do not exceed the recommended distances or pass wires
between buildings.
The potential for damage from lightning strikes increases if wires
exceed recommended distances or if wires pass between
buildings.
Shield all conductors.
The electromagnetic pulse (EMP) caused by lightning can
damage unshielded conductors and destroy electronic devices.
Signaling Limitations
37Copyright © 2015, Juniper Networks, Inc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX110 H2 and is the answer not in the manual?

Juniper SRX110 H2 Specifications

General IconGeneral
Form FactorDesktop
VPN Throughput65 Mbps
Maximum Concurrent Sessions16, 000
Memory1 GB DRAM
Flash Memory256 MB
Power SupplyExternal AC adapter
Humidity10% to 90% non-condensing
Weight2.5 lbs
Operating Temperature32°F to 104°F (0°C to 40°C)
Ports8 x 10/100/1000BASE-T