Make sure all covers and safety guards are in place and secured before re-starting.
Temperature
Do not touch hot components!
These include, for example, compressor blocks, compressed air lines, coolers, motors and ma‐
chine heaters.
Wear protective clothing.
If welding is carried out on or near the machine, take adequate measures to prevent sparks or
heat from igniting oil vapours or parts of the machine.
Noise
Operate the machine only with intact sound insulation.
Use hearing protection when appropriate.
The pressure relief valve blowing off can be particularly loud.
Operating fluids/materials
Strictly forbid fire, open flame and smoking.
Follow safety regulations when dealing with oils, lubricants and chemical substances.
Avoid contact with skin and eyes.
Do not inhale oil mist and vapours.
Do not eat or drink while handling cooling and lubricating fluids.
Keep suitable fire extinguishing agents ready for use.
Use only KAESER approved operating materials.
Unsuitable spare parts
Use only spare parts approved by the manufacturer for use in this machine.
Unsuitable spare parts compromise the safety of the machine.
Use only genuine KAESER replacement parts on pressure bearing parts.
Conversion or modification of the machine
Do not permit conversion or modification of the machine as this can compromise function and
safe working.
Extending or modifying the compressor station
If a compressor station is to be extended or changed,
check the blow-off capacity of the pressure relief valves on air receivers and pipework before
installing the new devices.
Pressure relief valves of insufficient blow off capacity
must be replaced by valves with a higher capacity.
3.5.2 Safe machine operation
Information on safe conduct when handling the machine is found here.
3 Safety and Responsibility
3.5 Dangers
16
Service Manual 2-stage piston compressor
EPC No.: 9_9431_02 E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER EPC Series and is the answer not in the manual?

KAESER EPC Series Specifications

General IconGeneral
TypeRotary Screw Compressor
Drive TypeDirect Drive
Cooling SystemAir-cooled
Control SystemSigma Control 2.0
WeightVaries depending on model
Noise Level62 - 75 dB(A) (depending on model)