Fault Possible cause Remedy
Machine uses too much oil. Viscosity too low. Fill with oil specified in the ser‐
vice manual.
Crankcase venting defective. Clean or renew the crankcase
vent.
Piston rings worn or broken. Contact KAESER service.
Piston rings already worn or
damaged after only a short op‐
erating period.
Dirty oil. Fit finer air inlet filter.
Tab. 30 Faults and remedies
9 Fault Recognition and Rectification
9.2 Alarms
No.: 9_9431_02 E
Service Manual 2-stage piston compressor
EPC
45