Fig. 29 Starting instruments
1 «Controller on » switch
2 «Starter switch »
– STOP/Off
– On
– START
3
– «Full load mode ON» pushbutton
with integrated
FULL LOAD MODE
control
lamp.
4
Back-pressure
indicator
5
Charging indicating light, group alarm
lamp
6 Compressed air outlet pressure gauge
7 Temperature gauge switch
8 Operating hours counter
9
Fuel level monitoring
combination indi‐
cator lamp
10
Indicator
fault on the diesel particulate filter
(Option lc only)
Notes concerning snow and ice
Considerable snow or ice may build up on the machine under low temperature conditions.
Remove any snow and ice from the machine before operating.
8.2.1 Commissioning the machine
1. Open the right-hand access door.
2. Turn the «Controller On» switch.
3. Close the access door.
4. Turn the «starter switch» to "ON".
The
charging indicating light
must light.
8 Operation
8.2 Starting and stopping
64
Service manual Portable compressor
M122 No.: 9_6974 20 E
RAMIRENT