The two pulse inputs are identically constructed and can be individually set up to receive pulses from water
meters of max. 0.5 Hz.
Correct pulse value has been configured from the factory on the basis of order information, or is configured by
means of METERTOOL. See paragraph 3.6 concerning configuration of VA (FF-codes) and VB (GG-codes).
MULTICAL
The registration, which can both be read from the display (selecting a suitable DDD-code) and via data
communication, includes the following as well as date indication of yearly and monthly data:
402 registers the accumulated consumption of the meters connected to VA and VB and saves the
counter values every month and every year on target date. In order to facilitate identification during data reading
it is also possible to save the meter numbers of the two meters connected to VA and VB. Programming via
METERTOOL or via the front keys.
Type of registration:
Counter value Identification Yearly data Monthly data
VA (accumulated register)
Meter number VA
Yearly data, up to latest 15 years
Monthly data, up to latest 36 months
VB (accumulated register)
Meter number VB
Yearly data, up to latest 15 years
Monthly data, up to latest 36 months
By means of METERTOOL counter values VA and VB can be preset to the values of the connected meters at the
time of commissioning.