MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
67
10 Power supply
MULTICAL
®
Type 402-
402 must always be internally supplied with 3.6 VDC (± 0.1 VDC) via the built-in supply plug.
Supply
No module
0
Battery, 2 x AA
1
Battery, D-cell
2
230 VAC supply module
7
24 VAC supply module
8
The four above-mentioned supply modules are included in the comprehensive type test, to which MULTICAL
®
Note: MULTICAL
402
has been subjected. Within the framework of the type approval, the CE-declaration and the manufacturer’s
guarantee no other types of power supplies than the ones listed above can be used.
®
402 cannot be supplied by 24 VDC.
10.1 Built-in 2 x AA-cell lithium battery
The 2 x AA-cell lithium battery is in most applications sufficient to power MULTICAL
®
402 throughout an operating
period of 6 years (see paragraph 10.3).
Note: AA-cell lithium batteries include approx. 0.7 g lithium each and are therefore
not
comprised by transport
restrictions.