9
2.2 Electrical data
Calculator data
Typical accuracy
Calculator: E
C
Sensor set: E ± (0.15 + 2/Θ) %
T
Display
± (0.4 + 4/∆Θ) %
LCD 7 (8) digits with digit height 7.6 mm
Resolution 9999,999 99999,99 999999,9 9999999
Energy units MWh kWh GJ Gcal
Data logger (Eeprom) 460 days, 36 months, 15 years, 50 info codes
Clock/calendar
Clock, calendar, leap year compensation, target date
Data communication KMP protocol with CRC16 used for optical communication
as well as modules.
Power of temperature
sensors
< 10 µW RMS
Supply voltage
3.6 VDC ± 0.1 VDC
Battery 3.65 VDC, D-cell lithium 3.65 VDC, 2xAA cell lithium
Replacement interval
- Wall mounted
- Mounted on flow
sensor
16 years @ t
BAT
12 years @ t
< 30 °C
BAT
< 40 °C
6 years @ t
BAT
5 years @ t
< 30 °C
BAT
Data modules, frequent data communication and high ambient temperature
reduce the replacement interval (See paragraph 10.3 and 10.4)
< 40 °C
Mains supply
230 VAC +15/-30%, 50/60 Hz
24 VAC ±50%, 50/60 Hz
Insulation voltage 4 kV
Power consumption
< 1W
Backup supply
Integral SuperCap eliminates interruptions due to short-term power failures
EMC data Fulfil EN 1434 class A (MID class E1)
Temperature measurement
T1
Forward
temperature
T2
Return
temperature
∆Θ
(T1-T2)
Heat
metering
∆Θ
(T2-T1)
Cooling
metering
402-V
2-W Pt100
Measuring
range
0.00…165.00°C 0.00…165.00°C
0.01…165.00K 0.01…165.00K
402-W/T
2-W Pt500
Measuring
range
0.00…165.00°C 0.00…165.00°C
0.01…165.00K 0.01…165.00K
Max. cable lengths Pt100, 2-wire Pt500, 2-wire
(Max. ø6 mm cable) 2 x 0.25 mm
2
2 x 0.50 mm
: 2.5 m
2
2 x 1.00 mm
: 5 m
2
2 x 0.25 mm
: 10 m
2
2 x 0.50 mm
: 10 m
2
: 20 m