MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
33
6.4 Installation examples
Figure 11: Threaded meter
Mounting of glands and short direct sensor mounted in MULTICAL
®
The short direct sensor from Kamstrup can only be mounted in PN16 installations. The blind plug mounted in the
MULITCAL
402 flow part (only G¾ (R½) and G1(R¾)).
®
402 flow part can be used in connection with both PN16 and PN25.
The flow meter can be used in both PN16 and PN25 and can be supplied marked either PN16 or PN25 as desired.
Possibly supplied glands can only be used for PN16. For PN25 installations shall be used suitable PN25 glands.
In connection with G¾x110 mm and G1x110 mm it shall be checked that 10 mm thread run-out is sufficient.
Figure 13: Flange meter
Figure 12
Flow
*Gasket
Torque approx 4 Nm
Flow
Flow
Flow