EasyManua.ls Logo

Kamstrup MULTICAL 402 - Battery Lifetimes of D-Cell

Kamstrup MULTICAL 402
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MULTICAL® 402
70
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
10.4 Battery lifetimes of D-cell
Estimated battery lifetime in years
Normal response (24 s.) Fast response (4 s.)
D-cell battery
Wall mounted
Battery < 30°C
Pipe mounted
Battery < 40°C
Wall mounted
Battery < 30°C
Pipe mounted
Battery < 40°C
402-0-00
Without module
16 12 8 6
402-0-10
Data + 2 pulse inputs (VA, VB)
Monthly: 16
Daily: 16
Hourly: 12
Min.: -
Monthly: 12
Daily: 12
Hourly: 10
Min.: -
Monthly: 8
Daily: 8
Hourly: 6
Min.: -
Monthly: 6
Daily: 6
Hourly: 5
Min.: -
402-0-11
Data + 2 pulse outputs (CE, CV) *)
Monthly: 10
Daily: 8
Hourly: 6
Min.: -
Monthly: 8
Daily: 6
Hourly: 5
Min.: -
- -
402-0-20
M-Bus + 2 pulse inputs (VA, VB)
Monthly: 16
Daily: 16
Hourly: 12
Min.: -
Monthly: 12
Daily: 12
Hourly: 10
Min.: -
Monthly: 8
Daily: 8
Hourly: 6
Min.: -
Monthly: 6
Daily: 6
Hourly: 5
Min.: -
402-0-21
M-Bus + 2 pulse outputs (CE, CV)*)
Monthly: 10
Daily: 8
Hourly: 6
Min.: -
Monthly: 8
Daily: 6
Hourly: 5
Min.: -
- -
402-0-29
M-Bus + 2 pulse inputs (VA, VB), MCIII Data Package
Monthly: 16
Daily: 16
Hourly: 12
Min.: -
Monthly: 12
Daily: 12
Hourly: 10
Min.: -
Monthly: 8
Daily: 8
Hourly: 6
Min.: -
Monthly: 6
Daily: 6
Hourly: 5
Min.: -
402-0-30/31/35/38
Wireless M-Bus, EU, 868 MHz, Mode C1
Wireless M-Bus, EU, 868 MHz, Mode T1 OMS (Ind. Key)
Wireless M-Bus, EU, 868 MHz, Mode C1 (Ind. Key) Alt. Reg . +VA, VB
Wireless M-Bus, C1, Fixed Network, (Ind. Key)
16 12 8 6
402-0-37
Wireless M-Bus, EU, 868 MHz, Mode T1 (Common Key)
11 8 6 5
402-0-40/41 (By hand-held systems)
Radio, EU, 434 MHz, int. ant.
Monthly: 12
Daily: 11
Hourly: -
Min.: -
Monthly: 10
Daily: 9
Hourly: -
Min.: -
Monthly: 6
Daily: 5
Hourly: -
Min.: -
Monthly: 5
Daily: 4
Hourly: -
Min.: -
402-0-42/44
Radio, EU, 434 MHz, int.+ext. ant.+
2 pulse inputs (VA, VB)
Monthly: 12
Daily: 11
Hourly: -
Min.: -
Monthly: 10
Daily: 9
Hourly: -
Min.: -
Monthly: 6
Daily: 5
Hourly: -
Min.: -
Monthly: 5
Daily: 4
Hourly: -
Min.: -
402-0-43/45
Radio, EU, 434 MHz, int.+ext. ant +
2 pulse outputs (CE, CV) *)
Monthly: 8
Daily: 7
Hourly: -
Min.: -
Monthly: 6
Daily: 5
Hourly: -
Min.: -
- -
402-0-50/52/54/56
Radio, SE, 444 MHz, int. ant./ ext. ant. +
2 pulse inputs (VA, VB)
Monthly: 12
Daily: 11
Hourly: -
Min.: -
Monthly: 10
Daily: 9
Hourly: -
Min.: -
Monthly: 6
Daily: 5
Hourly: -
Min.: -
Monthly: 5
Daily: 4
Hourly: -
Min.: -
*) Pulse duration: 32 ms. -Standard CCC-code Average flow: 30% of qp –Average cooling: < 40 K