EasyManua.ls Logo

Kamstrup MULTICAL 402 - True Energy Calculation; Multical

Kamstrup MULTICAL 402
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
93
13.4 True energy calculation
During test and verification the heat meter’s energy calculation is compared to the ”true energy” calculated
according to the formula of EN 1434-1:2007 or OIML R75:2002.
The PC-program METERTOOL from Kamstrup includes an energy calculator which is suitable for this purpose:
The true energy at the most frequently used verification points is indicated in the table below.
T1
[°
C
]
T2
[°
C
]
∆Θ
[
K
]
Flow
[
Wh/0.1 m
3
Return
]
[
Wh/0.1 m
3
]
42 40 2 230,11 230,29
43 40 3 345,02 345,43
53 50 3 343,62 344,11
50 40 10 1146,70 1151,55
70 50 20 2272,03 2295,86
80 60 20 2261,08 2287,57
160 40 120 12793,12 13988,44
160 20 140 14900,00 16390,83