3.8.2 Configuration data
During the production of MULTICAL
®
402 values must be entered in the below-mentioned fields. Unless otherwise
specified in the order, MULTICAL
®
402 will be supplied with the below-mentioned ”Automatic” and ”Default”
data.
Automatic
To be stated when ordering Default
Serial no. (S/N) as well as
60.000.000/2010 - -
Customer No.
Display No. 1 = 8 digits MSD
Display No. 2 = 8 digits LSD
-
Up to 16 digits
Limited to 11 digits in BOS
dep. on PcBase compatibility
Customer number = S/N
Target date - MM=1-12 and DD=1-28 Dep. on country code
- 1…1440 min. 60 min.
θ
hc
-
Heat/cooling switching
0.01…160.00°C *) 25.00°C
Date/time
YYYY.MM.DD/hh.mm.ss
GMT+offset acc.to country
code
GMT ± 12.0 hours
(30 min. in leaps)
-
*)
θ
hc
S/N 60.000.000 to 62.499.999 have been reserved for MC402.
= 180.00
°
C switches off the function so that the meter can be used for ”purchase/sales” of heat
3.8.3 Customer label
In the top left corner of the type label an area of 15 x 38 mm has been reserved for customer labels (see
paragraph 3.1), which can include e.g. the logo of a utility, a bar code etc. Unless otherwise specified in the order,
MULTICAL
®
Please contact Kamstrup for the creation of new customer labels.
402 will be supplied with customer label no. 2001-000, which includes the meter’s customer number.
3.8.4 Other functions
Creating an order in BOS you can choose ”fixed M-Bus addr” which means that all meters included in the ordre in
question will be given the same M-Bus address.
3.8.5 Internal configuration survey
See instructions no. 5508-739 concerning update of programming and configuration.