- 96-
F6.02 Data pattern
0: No checkN81for RTU
1: Odd checkE81for RTU
2: EvencheckO81for RTU
4: Odd checkE82for RTU
5: EvencheckO82for RTU
6: No checkN71forASCII
7: Odd checkE71for ASCII
8: EvencheckO71forASCII
9: No checkN72forASCII
10: Odd checkE72for ASCII
11: EvencheckO72forASCII
12: No checkN81forASCII
13: Odd checkE81for ASCII
14: EvencheckO81forASCII
15 : No checkN82forASCII
16: Odd checkE82for ASCII
17: EvencheckO82forASCII
0
The data pattern set by inverter must be the same as data pattern set bymaster
machine.Otherwise,communication can not accomplish.
11-bits(for RTU)
DATA Frame:8-N-2
DATA Frame:8-E-1
DATA Frame:8-O-1