ACD320 user manual Parameter Description
- 98-
When this parameter is set to be 0.0s, this function is invalid.
When this function is valid, if the interval time between two communications exceeds
communication overtime time, it will cause communication fault (U-16).
Normally
,
it is set to be ineffective. Cmmunication status can be monitored by setting the
parameter in continuous communication system.
Function Code Name Setting Range
Default
Value
F6.05 Communication er ror
measure
0: Alarmand free run
stop
1: No alarm and keep
running
2 : No alarm and stop
according to stop mode
(by communication)
3: No alarm and stop
according to stop mode
(by all control mode)
1
The inverter can shield the failure alarm and stop to keep running by setting protecting
action selection in abnormal communication condition.
Function Code Name Setting Range
Default
Value
F6.06 Response measure
0: Response when write
1: No response when write
0
When this parameter is set to be 0, Response when write.
When this parameter is set to be 1, No Response whenwrite.This function can improve
communiation speed.
6.8 F7 Senior Function Parameters
Function Code Name Setting Range
Default
Value
F7.00
The choice of
constant pressure
water supply mode
0: One driving two circularly
water supply mode is ineffective
1: One driving two circularly
water supply mode is ineffective
0
When one driving two water supply circle mode is effective,the water supply card is a