EasyManua.ls Logo

K&R ACD320 Series - FDT Level Diagram

K&R ACD320 Series
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACD320 user manual Parameter Description
- 85-
F4.11 Fault auto-reset times 03 0
F4.12
Interval time setting of
automatic resetting fault
0.1100.0s 1.0s
Fault auto-reset times: used to set the auto-reset times when inverter chooses fault auto-reset.
If this value is exceeded, inverterwill wait for trouble shooting.
Interval time setting of fault auto-reset: chose the interval time between fault occurring and
automatic resetting actuated.
Function Code Name Setting Range
Default
Value
F4.13 FDT level detection value 0.00 F0.04 50.00Hz
F4.14 FDT delay detection value 0.0100.0%(FDTlevel) 5.0%
Set output frequency detection value and the delay value of output action dismissed, as
shown by following figure:
Fig.6-16 FDT LevelDiagram
Function Code Name Setting Range
Default
Value
F4.15 Frequency reaching
detection range
0.0100.0%(maximum
frequency)
0.0%
When the inverter output frequency reaches the set frequency value, this function can
regulate its detect ion range value, as shown by following figure:

Table of Contents