System operation
Example schematic diagram Example 1:
50%
Hysterese
hysteresis
A
B
cosphi
0,90
0,90
cosphi1 = 1,0
übererregt
over-exited
(kapazitiv
capactiv)
untererregt
under-exited
(induktiv
inductiv)
100%
5V
10V
0%
50%
100%
Einstellbereich in %
setting range in %
0V
Example settings:
Cosphi1 1.00
Mode AI 3 φ
t-delay 000 seconds
Q-Control No
cosφ A 0.90 ind.
from (%) 0%
to (%) 50%
cosφ B 0.90 cap.
from (%) 50%
to (%) 100%
AI 2-10 V No
Hysteresis 0.00%
Function:
With an input voltage of 0V (= 0%) the instantaneous target-cosφ would be 0.95 ind.
With an input voltage of 5V (= 50%) the instantaneous target-cosφ would be 1.0.
With an input voltage of 10V (= 50%) the instantaneous target-cosφ would be 0.95 cap.