342
Checking the
Unintended
Movement Funcon
Make sure the inverter status
is “No Operaon” and mode
is “Idle”
Drive trips
Unintended
Movement?
Yes
Release the brake so the car
dris more than the
unintended movement
distance
Reset the error
Error is
reset?
Funcon works as intended
Yes
Funcon is not properly
working. Check sengs and
connecons.
No
No
Complete a normal run
Restore the brake to normal
12.2 Unintended Movement Test
Refer to parameters LX21 Unintended Motion and LX25 Unintended Motion Distance.
Brake Release Conrmation Tests