US - Basic Setup Parameters
This parameter chooses to display the speed, accel, and torque units in either
Imperial or Metric format.
Settings: NUM
m / sec 0
ft / min 1
Default = ft / min
This parameter chooses the motor type and gearing conguration of the
system.
Settings: NUM
Induction Geared 0
Induction Gearless 1
PM synchronous Geared 2
PM synchronous Gearless 3
Default = Induction Geared
Changing to a new conguration will return the parameter values to de-
fault! If a new conguration is loaded, users must go through all start-up
steps before running the motor.
6.1 US - Basic Setup Parameters