TS - Terminal Slowdown Parameters
Overview
The terminal slowdown parameters congure the settings for inputs assigned
as Normal Terminal Slowdown (NTS) inputs. (LI04-11).
The purpose of the NTS inputs is to provide an expedited and/or an alternate
slowdown means when the elevator speed approaching a terminal landing is
greater than a dened level. If this level is exceeded, the drive will perform
an NTS stop; otherwise, the drive will continue as normal.
Up to three NTS speed thresholds in each direction can be set with each input
corresponding to an NTS speed threshold or two inputs can be binary-coded
(TS01 NTSD Mode). This provides multiple checks during slowdown as the
contract speed increases.
Speed
LS02
TS02
Direction
Dropped
NTSD 1
Speed
NTSD 2
Speed
NTSD 3
Speed
6.17 TS - Terminal Slowdown Parameters

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals