CH - Conguration Handling
The Conguration Handling parameter group has the same functions as US05
Load Conguration, which is only accessible with the OEM level password
or higher.
The drive can be reverted back to default settings. The default settings are
customizable and may vary from those from KEB. The default settings must
be created using US05= 8 (create OEM default). To completely default the
keypad to KEB default settings, go to CH01 and select PI password (2).
Setting: Description: NUM
Off No action taken 0
Factory Reset Will load defaults, as created by controller
OEM
1
PI Password Revert to KEB keypad default settings 2
All current parameter settings can be saved to ash memory on the keypad
operator for future access. Or, current keypad operator settings can be
downloaded to the drive if a new or different keypad operator is installed.
Saving to the ash provides a ‘backup point’ during adjustment and allows a
user to revert back to known settings.
Setting: Description: NUM
Off No action taken 0
Save to Flash All current parameter settings are saved to keypad
operator ash memory
1
Save to Card This function is not available 2
Write to Drive Current keypad operator settings downloaded to
drive
3
Previously saved parameters can be restored from keypad operator ash
memory to revert to previous settings. Or, current drive settings can be
uploaded from the drive onto a new or different keypad operator.
Setting: Description: NUM
Off No action taken 0
Restore from Flash Previously saved parameter settings are
restored from internal keypad operator
ash
1
Load Parameter List* Loads data from .dw5 stored to ash. 2
Restore from Drive Current drive settings are uploaded from
drive to keypad operator
3
Load Motor Data* Loads data from .dw5 stored to ash. 4
6.12 CH - Conguration Handling Parameters
CH01
Default Parameters
CH02
Save Parameters
CH03
Restore Parameters

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals