EasyManuals Logo

KEB COMBIVERT F5 Reference Manual

KEB COMBIVERT F5
349 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
109
Parameters Descriptions
The programming menu is where all manual parameter adjustments are
made and can be accessed at Home > Prog (F3).
The Parameter menu contains the following groups:
Operator System: OS00...OS25
These parameters provide general information about the operator
and drive hardware and software. Additionally, the operator password
level is set here, which allows for different access levels.
Conguration Handling: CH01...CH15
These settings allow a user to save parameters and default to OEM
settings.
Basic Setup: US02...US06
These parameters provide the very basic information needed to
congure the drive, including: motor type, control type, and contract
speed.
Inputs: LI01...LI60
These parameters dene the logic of the inputs and assign control
functionality to the digital inputs.
Motor Data: LM01...LM33
These parameters dene and display all relevant motor values and
motor protection settings.
Encoder Data: LE01...LE36
These parameters dene the settings and scalings of the drive
encoders
Machine Data: LN01...LN05
These parameters dene the machine data, including: sheave
diameter, roping ratio, and rated load values.
Speed Prole: LS00...LS55
These parameters adjust the speed, acceleration, and jerk values
across the elevator run prole.
Tune Parameters: LL01...LL18
These parameters contain automatic tuning parameters.
Here you can learn the system inertia, motor data, and motor pole
positions.
6.Parameter Description

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)