235
FB - Field Bus Parameters
DIN66019II Serial Protocol
The DIN66019II serial protocol consists of various services, which are dened
telegram structures for serial communication between controller and keypad
operator.
DIN66019II services 48, 49, and 50 will be supported. There will be an
independent watchdog timer for the serial interface, the node ID will be
adjustable from 1 to 128, and the available baud rates will be 9,600, 19,200,
38,400, 55,500, and 115,200.
• Service 48 = 2x32-bit
• Service 49 = 4x16-bit
• Service 50 = 2x16-bit + 1x32-bit + 1x32-bit AUX R/W*
*Service 50 AUX parameter channel can be used to access any read-only
inverter or keypad operator parameter. Write capability is limited to operator
parameters and only while the inverter status is Mode = Idle.
6.15 FB - Field Bus Parameters

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals