Operation Manual ServoOne Supply Unit
60
ID no.: 1101.21B.6-00 Date:04/2020
= selected setting/component
Connections Terminals Terminal identifier Cable type
Control supply X9/10 +24VDC / pin 1 = + , pin 2 = – Standard
Precharging/mains
synchronisation, auxiliary
relay
X21
L1/L2/L3 (400/460/480V
AC
)
HREL
Standard
shielded
Mains supply X12 L1/L2/L3/PE (400/460/480V
AC
)
Standard
shielded
See chap.4.3, p.33
Table 5.1 Power supply
Connection Socket Designation Cable type
USB X2 USB A CC-USB 03
TCP / IP (Ethernet) X3 RJ45
Commercially
available cross
link cable Cat
5e/ shielded
or better
Table 5.2 Communication with the PC with user software DriveManager 5
Connection Terminals Terminal identifier Cable type
+24VDC X4/22 ISDSH
Standard
shielded
ENPO (Start) X4/10 ENPO
Standard
shielded
See chap.4.9, p.51
Table 5.3 Communication via terminals
5.2.1 System requirements
y Supply unit installed.
You will nd details on initial commissioning in chap.5.2.2, p.60
y Completion of the work in chap.4 "Electrical installation" and chap. 3 "Starting
DriveManager5" in the Installation Manual DriveManager5
y Connection between PC and ServoOne supply unit (Ethernet or USB)
NOTE:
During commissioning, please follow the safety instructions in chap.2
5.2.2 Wiring the components
1.
Forcompletewiringthecableconnections,thecommunicationandserviceconnectionsmustbe
connectedusingtherelatedcablesandwiresattheterminalsprovidedforthispurpose.
Payattentiontoadequateshielding.
Commissioning